The increasing penetration of inverter-based resources (IBRs) has fundamentally altered the transient stability characteristics of modern power systems. IBRs typically rely on proportional–integral (PI) controllers for synchronization and regulation, resulting in nonlinear swing equations that differ significantly from those of synchronous generators (SGs) and exhibit state-dependent damping. Consequently, although the classical energy function is often adopted in IBR analysis by analogy with SGs, it cannot be directly applied to IBRs with PI controller. A new energy function explicitly tailored to PI controller is proposed in this letter. It admits a unified form and can be applied to a class of nonlinear systems with PI controllers. Two representative cases are considered, including a grid-following (GFL) inverter and a DC-voltage-controlled grid-forming (GFM) inverter, demonstrating less conservative and more effective estimation of the region of attraction (ROA). All findings are verified through hardware-in-the-loop (HIL) experiments.