The specific activity of the beta decay of Ar in atmospheric argon is measured using the DEAP-3600 detector. DEAP-3600, located 2 km underground at SNOLAB, uses a total of (3269 24) kg of liquid argon distilled from the atmosphere to search for dark matter. This detector with very low background uses pulseshape discrimination to differentiate between nuclear recoils and electron recoils and is well-suited to measure the decay of Ar. With 167 live-days of data, the measured specific activity at the time of atmospheric extraction is [0.964 0.001 (stat) 0.024 (sys)] Bq/kg which is consistent with results from other experiments. A cross-check analysis using different event selection criteria provides a consistent result.