We report the first isoelectronic differential force measurements between a Au-coated probe and two Au-coated films, made out of Au and Ge. These measurements, performed at submicron separations using soft microelectromechanical torsional oscillators, eliminate the need for a detailed understanding of the probe-film Casimir interaction. The observed differential signal is directly converted into limits on the parameters and which characterize Yukawa-like deviations from Newtonian gravity. We find for nm, an improvement of 10 over previous limits.