Sidles and Sigg have shown that advanced LIGO interferometers will encounter
a serious tilt instability, in which symmetric tilts of the mirrors of an arm
cavity cause the cavity’s light beam to slide sideways, so its radiation
pressure exerts a torque that increases the tilt. Sidles and Sigg showed that
the strength T of this torque is 26.2 times greater for advanced LIGO’s
baseline cavities – nearly flat spherical mirrors which support Gaussian beams
(FG'' cavities), than for nearly concentric spherical mirrors which support Gaussian beams with the same diffraction losses as the baseline case -- CG’’
cavities: T^{FG}/T^{CG} = 26.2. This has motivated a proposal to change the
baseline design to nearly concentric, spherical mirrors. In order to reduce
thermoelastic noise in advanced LIGO, O’Shaughnessy and Thorne have proposed
replacing the spherical mirrors and their Gaussian beams by Mexican-Hat'' (MH) shaped mirrors which support flat-topped, mesa’’ shaped beams. In this
paper we compute the tilt-instability torque for advanced-LIGO cavities with
nearly flat MH mirrors and mesa beams (FM'' cavities) and nearly concentric MH mirrors and mesa beams (CM’’ cavities), with the same diffraction losses
as in the baseline FG case. We find that the relative sizes of the restoring
torques are T^{CM}/T^{CG} = 0.91, T^{FM}/T^{CG} = 96, T^{FM}/T^{FG} = 3.67.
Thus, the nearly concentric MH mirrors have a weaker tilt instability than any
other configuration. Their thermoelastic noise is the same as for nearly flat
MH mirrors, and is much lower than for spherical mirrors.