In the DeeMe experiment, approximately prompt-charged particles will hit the multi-wire proportional chambers (MWPCs) before signal electrons come. To avoid the space charge effect, we developed fast HV-switching MWPCs in order to control the gas gain dynamically. All four of the MWPCs were manufactured. Last year, the circuit of readout amplifiers is slightly modified to further improve the efficiency of the detector, and we also started to investigate other possible choices of the gas mixture. In this article, the development of the detectors and results of performance tests will be presented.