There are heuristic arguments proposing that the accuracy of monitoring
position of a free mass is limited by the standard quantum limit
(SQL):$\sigma^2 (X(t)) \geq \sigma^2 (X(0)) +(t^2/m^2) \sigma^2 (P(0))\geq
\hbar t/m\sigma^2 (X(t))\sigma^2 (P(t))$ denote variances of
the Heisenberg representation position and momentum operators. Yuen discovered
that there are contractive states for which this result is incorrect. Here I
prove universally valid rigorous quantum limits (RQL) viz. rigorous upper and
lower bounds on in terms of and $\sigma^2
(P(0))$ for a free mass, and for an oscillator. I also obtain the maximally contractive' and maximally expanding’ states which saturate the RQL, and use
the contractive states to set up an Ozawa-type measurement theory with
accuracies respecting the RQL but beating the standard quantum limit. The
Contractive states for oscillators improve on the Schr"odinger coherent states
of constant variance and may be useful for gravitational wave detection and
optical communication.