5-cell elliptical cavities are chosen for the main linac of China Accelerator Driven sub-critical System in the medium energy section. Each cavity is driven by one fundamental power coupler delivering RF power up to 150 kW. A single window, coaxial type coupler satisfying high power requirements, class 10 clean room assembly with cavity and low heat load simultaneously was designed. This paper gives the details of RF design, external Q calculation and thermal analysis as well as multipacting simulations of the coupler.