In this paper, blackbody radiation (BBR) temperature rise seen by the Ca ion confined in a miniature Paul trap and its uncertainty have been evaluated via finite-element method (FEM) modelling. The FEM model was validated by comparing with thermal camera measurements, which were calibrated by PT1000 resistance thermometer, at several points on a dummy trap. The input modelling parameters were analyzed carefully in detail, and their contributions to the uncertainty of environment temperature were evaluated on the validated FEM model. The result shows that the temperature rise seen by Ca ion is 1.72 K with an uncertainty of 0.46 K. It results in a contribution of 2.2 mHz to the systematic uncertainty of Ca ion optical clock, corresponding to a fractional uncertainty 5.410. This is much smaller than the uncertainty caused by the BBR shift coefficient, which is evaluated to be 4.8 mHz and at 10 level in fractional frequency units.