Future liquid-xenon (LXe) based observatories for rare processes, such as XLZD, require testing of large components and sub-assemblies in cryogenic liquid or gaseous xenon environments. Here we present results from the stable operation of a shallow dual-phase LXe TPC with an inner diameter of 133.4,cm and a height of 3.1,cm in the unshielded PANCAKE platform, without underground suppression of cosmic-ray backgrounds. A total of 340,kg of xenon was used in the experiment, of which 127,kg constituted the active TPC mass. Measurements of the LXe purity-dependent electron lifetime and the electron drift velocity in LXe demonstrate that sensitive measurements to characterize the TPC performance are possible in a high-background environment, even with a very basic PMT-based light detection system. Improving this will straightforwardly reduce the TPC threshold, which was observed to be around 15,keV for electronic recoils in TPC operation.