Water Cherenkov detectors offer a robust and economical solution for real-time radiation monitoring by detecting Cherenkov light from charged particles moving faster than light in water. This work presents a novel two-stage classification framework for gamma-neutron discrimination: an initial physics-based energy threshold filters unambiguous low-energy gamma sources, followed by a machine learning ensemble that resolves ambiguities at higher energies. The detector response was characterized using Co (1.17/1.33~MeV), Cs (0.66~MeV), and a shielded AmBe source, with lead, paraffin, and cadmium shielding employed to isolate neutron and gamma interactions. Energy calibration established a linear ADU to MeV conversion (), enabling identification of a neutron detection threshold at ~MeV via a significance analysis. Stage one categorizes sources as pure gamma (below threshold) or neutron-emitting (at threshold). For ambiguous cases above threshold, a machine learning pipeline utilizing pulse shape analysis was developed. A soft voting ensemble (Bagging, CatBoost, and MLP) achieved an accuracy of 0.816 and an AUC of 0.921. This hybrid scheme combines physics-based filtering with ML refinement, offering an interpretable and scalable solution for nuclear security, nonproliferation monitoring, and fundamental radiation research.