The Silicon Beam Tracker (SiBT) of the BM@N experiment at the NICA complex (JINR, Dubna) is designed to reconstruct trajectories of beam ions upstream of the target. It consists of three stations based on double-sided silicon strip detectors (DSSDs) installed directly in the relativistic heavy-ion beam. The SiBT performance and radiation damage were studied using data from the 2026 experimental run with Xe beams at~,~, and~~AGeV. During the run, the leakage current of the DSSD of the third station of SiBT increased by , while the charge collection efficiency in the beam center decreased to approximately at the nominal bias voltage of 30~V. Increasing the bias voltage to 90~V restored the charge collection efficiency to approximately . Despite the radiation-induced signal degradation, the tracking efficiency remained close to . The accumulated radiation damage was also used to reconstruct the spatial distribution of the integrated beam fluence from strip-by-strip leakage-current measurements, yielding an average fluence of approximately .