加载中…
A recent Letter by Wadhia et al. reports a realization of a quantum clock using a double quantum dot (DQD) [Phys. Rev. Lett. 135, 200407 (2005)]. This Comment identifies two fundamental issues: (I) the claimed ``quantum clock" exhibits only classical behavior and lacks intrinsic temporal correlations between ticks; it is not sufficient for accurate time as a good clock. (II) the thermodynamic analysis misassigns entropy production and conflates amplification with measurement; the reported combined entropy is an engineering dissipation, not a fundamental cost of quantum timekeeping.